TonnageMapHow many tons your house actually needs, and what the swap costs.

What size AC does a 3000 sq ft house in New South Memphis, TN need?

3,000 ft² in New South Memphis, TN
5tons
75,035 BTU/hr — 600 ft² per ton at a 96°F design day
3,000 ft² in New South Memphis, TN5 tonsNominal size to b…6.25 tonsCalculated need5,829 kWh/yrCooling energy at…7.3 tonsSame house on the…
Nominal size to buy5tons
Calculated need3,000 ft² × 25 BTU/ft², interpolated from 2,417 cooling degree days6.25tons
Summer design temperature1% design dry bulb at Memphis International Airport — the level the air is above for 1% of the year's hours96°F
Winter design temperature99% design dry bulb — the number a heating load starts from18°F
Cooling design difference96°F outside against 75°F inside21°F
Summer day–night swingJune–August average — a moderately humid climate, and humidity is what sets the latent load18°F
Days at or above 90°F65days/yr
Cooling degree daysbase 65°F, annual average2,417°F-days
Heating degree daysbase 65°F, annual average2,650°F-days
Cooling energy at SEER 145,829kWh/yr
Cooling cost per yearat 16.7¢/kWh, the national residential average$971
Oversize from rounding upwithin the normal rounding step-20%
Equivalent full-load hourshow long the compressor runs at full output over a season1,088hr/yr
Same house on the Gulf coastaround 5,100 cooling degree days7.3tons
Same house in the upper Midwest1.58× spread for the identical building4.6tons

Notes

  • This is a rule of thumb keyed to New South Memphis's climate, not a Manual J. The tonnage above comes from 25 BTU per square foot. That figure is not a lookup: the industry's zone table turns out to be a degree-day table in disguise, so it is interpolated continuously against New South Memphis's own 2,417 cooling degree days — two cities in the same zone 800 degree-days apart do not get the same answer here. What New South Memphis actually contributes is the two design temperatures — 96°F in summer and 18°F in winter — and those are the numbers a real load calculation begins from. A house here with new windows and a sealed envelope can come in a full ton under this; a 1960s house with an uninsulated attic can come in a ton over.
  • New South Memphis is on the dry side — summer nights drop 18°F below the afternoon high, and only dry air lets heat radiate away like that. Latent load is small, so almost all of the capacity above goes into temperature rather than moisture. Two consequences: evaporative cooling is worth pricing here in a way it never is on the Gulf coast, and a slightly undersized unit is more forgiving than it would be in a humid climate, because it will still hold comfort even when it runs continuously on the hottest afternoon.
  • 65 days a year reach 90°F here, and the design temperature is 96°F. Equipment is sized for the 1% condition, not the hottest hour on record — which means on the hottest afternoons of the year this system is expected to run continuously and still drift a degree or two above setpoint. That is the intended behaviour. Sizing for the record high instead would leave the unit oversized for the other 361 days, short-cycling through all of them.
  • Bigger is not safer. An oversized compressor reaches setpoint and stops before it has run long enough to dehumidify, then starts again minutes later. Short cycling is the single most common cause of early compressor failure, and it is bought, not suffered.
  • Running cost, roughly. 2,417 cooling degree days works out to about 1,088 equivalent full-load hours here — the number of hours the compressor would run at full output if it ran flat out instead of cycling. At SEER 14 that is 5,829 kWh a season, about $971 at the national average rate. Moving to SEER 18 would cut it to roughly $755 a year — worth pricing seriously in a climate that runs this many hours.
  • About the climate figures. Everything above is computed from ERA5 reanalysis at New South Memphis's own coordinates over 2015–2024, not copied from a table: 2,650 heating and 2,417 cooling degree days, base 65°F. The zone shown alongside is derived from those degree days against the ASHRAE 169 boundaries — your building department assigns zones by county from older climate normals and may list a different one, so go by the county table when you are pulling a permit. City-centre readings also run a degree or two warmer than the airport station most published tables use.

The short answer

A 3000 square foot house in New South Memphis, TN needs about 5 tons — 75,035 BTU per hour, which is square feet per ton.

Where that number comes from

New South Memphis, TN sees 96°F on a design summer day and runs 2,417 cooling degree days in an average year. Feed those into the load and the house wants 25.011719208184743 BTU per square foot per hour.

The familiar "400 square feet per ton" rule works out to here instead, and that gap is the whole point of asking the question by city rather than by rule.

What the humidity does

The June-to-August dew point averages °F in New South Memphis, TN. Dew point, not temperature, is what decides how much of the machine's work goes into pulling water out of the air — and that work only happens while the compressor is running.

What it costs to run

At SEER 14, cooling this house through a New South Memphis, TN summer takes roughly 5,829 kWh, about $971 at the national average electricity price.

Before you buy

The number above is a rule of thumb sized to New South Memphis, TN's climate. A Manual J load calculation is the real answer, and it is the one that accounts for your windows, your insulation and your air leakage. Ask for it before signing.

Nearby sizes

Read more