What size AC does a 2400 sq ft house in East Flatbush, NY need?

2,400 ft² in East Flatbush, NY
5tons
50,944 BTU/hr — 480 ft² per ton at a 89°F design day
2,400 ft² in East Flatbush, NY5 tonsNominal size to b…4.25 tonsCalculated need1,958 kWh/yrCooling energy at…5.8 tonsSame house on the…
Nominal size to buy5tons
Calculated need2,400 ft² × 21.2 BTU/ft², interpolated from 1,196 cooling degree days4.25tons
Summer design temperature1% design dry bulb at John F. Kennedy Airport — the level the air is above for 1% of the year's hours89°F
Winter design temperature99% design dry bulb — the number a heating load starts from13°F
Cooling design difference89°F outside against 75°F inside14°F
Summer day–night swingJune–August average — a humid climate, and humidity is what sets the latent load15°F
Days at or above 90°F8days/yr
Cooling degree daysbase 65°F, annual average1,196°F-days
Heating degree daysbase 65°F, annual average4,478°F-days
Cooling energy at SEER 141,958kWh/yr
Cooling cost per yearat 16.7¢/kWh, the national residential average$326
Oversize from rounding upenough to matter — see the note18%
Equivalent full-load hourshow long the compressor runs at full output over a season538hr/yr
Same house on the Gulf coastaround 5,100 cooling degree days5.8tons
Same house in the upper Midwest1.58× spread for the identical building3.7tons

Notes

  • This is a rule of thumb keyed to East Flatbush's climate, not a Manual J. The tonnage above comes from 21.2 BTU per square foot. That figure is not a lookup: the industry's zone table turns out to be a degree-day table in disguise, so it is interpolated continuously against East Flatbush's own 1,196 cooling degree days — two cities in the same zone 800 degree-days apart do not get the same answer here. What East Flatbush actually contributes is the two design temperatures — 89°F in summer and 13°F in winter — and those are the numbers a real load calculation begins from. A house here with new windows and a sealed envelope can come in a full ton under this; a 1960s house with an uninsulated attic can come in a ton over.
  • In East Flatbush the humidity matters more than the heat. Summer nights fall only 15°F below the afternoon high, and that narrow swing is the signature of humid air — water vapour holds the night temperature up. It means a large share of the machine's work is pulling water out of the air, not lowering temperature — and that work only happens while the compressor is actually running. An oversized unit here cools the room fast, shuts off, and leaves the moisture behind: the house reads 75°F on the thermostat and still feels clammy. This is the climate where buying one size up "to be safe" backfires hardest, and where variable-speed equipment earns its price difference.
  • 8 days a year reach 90°F here, and the design temperature is 89°F. Equipment is sized for the 1% condition, not the hottest hour on record — which means on the hottest afternoons of the year this system is expected to run continuously and still drift a degree or two above setpoint. That is the intended behaviour. Sizing for the record high instead would leave the unit oversized for the other 361 days, short-cycling through all of them.
  • Rounding up to 5 tons puts this 18% above the calculated load. Nominal sizes jump in half-ton steps and there is nothing between them, so ask whether two-stage or variable-capacity equipment at this size makes sense — that hardware can run at part load and sidestep the oversizing, which single-stage equipment cannot.
  • Running cost, roughly. 1,196 cooling degree days works out to about 538 equivalent full-load hours here — the number of hours the compressor would run at full output if it ran flat out instead of cycling. At SEER 14 that is 1,958 kWh a season, about $326 at the national average rate. Moving to SEER 18 would cut it to roughly $254 a year — worth less here than the brochures suggest, because the system simply does not run enough hours to earn the difference back quickly.
  • About the climate figures. Everything above is computed from ERA5 reanalysis at East Flatbush's own coordinates over 2015–2024, not copied from a table: 4,478 heating and 1,196 cooling degree days, base 65°F. The zone shown alongside is derived from those degree days against the ASHRAE 169 boundaries — your building department assigns zones by county from older climate normals and may list a different one, so go by the county table when you are pulling a permit. City-centre readings also run a degree or two warmer than the airport station most published tables use.

The short answer

A 2400 square foot house in East Flatbush, NY needs about 5 tons — 50,944 BTU per hour, which is square feet per ton.

Where that number comes from

East Flatbush, NY sees 89°F on a design summer day and runs 1,196 cooling degree days in an average year. Feed those into the load and the house wants 21.226650087666904 BTU per square foot per hour.

The familiar "400 square feet per ton" rule works out to here instead, and that gap is the whole point of asking the question by city rather than by rule.

What the humidity does

The June-to-August dew point averages °F in East Flatbush, NY. Dew point, not temperature, is what decides how much of the machine's work goes into pulling water out of the air — and that work only happens while the compressor is running.

What it costs to run

At SEER 14, cooling this house through a East Flatbush, NY summer takes roughly 1,958 kWh, about $326 at the national average electricity price.

Before you buy

The number above is a rule of thumb sized to East Flatbush, NY's climate. A Manual J load calculation is the real answer, and it is the one that accounts for your windows, your insulation and your air leakage. Ask for it before signing.